Környezetvédelmi technológia területén fő erősségünk az újrahasznosítható hulladékok optoelektronikai válogatása. Fő feladatunk üres üvegek feldolgozása, műanyag (italcsomagolások) válogatása és kartondobozok elkülönítése a papírtól |
biznestype : |
Manufacturer |
Környezetvédelmi technológia területén fő erősségünk az újrahasznosítható hulladékok optoelektronikai válogatása.
Fő feladatunk üres üvegek feldolgozása,
műanyag (italcsomagolások) válogatása és kartondobozok elkülönítése a papírtól
working in the field of enviromental and specialy in emission control technology, mainly dioxins and dust Continuous Dust monitors,Amalgam standard probes
The Company bm becker messtechnik gmbh is working in the field of enviromental and there special in emission control technology. A high grade of quality and custumer specified solution are developed due to the long experiences of our specialists. We are able to offer economically priced products according the requirements and demands of our customers.
 | Adsorption Method forSampling of Dioxins and Furans Applications
The continuous monitoring of dioxin and furan emissions of incinerators is a topic which has been discussed globally over the last several years. Even though a continuous on-line monitoring system would be the optimum solution, such systems are not available. Therefore, long-term sampling using AMESA could close the gap between reality and target results. AMESA provides more informations on dioxin emissions than the usual short-term collection of samples over a few hours on 1 – 3 selected days per year.
The TUV approved AMESA monitoring system is used for measuring dioxin/furanemissions in plants which have to be approved and are subject to the German environmental regulations 17. BImSchV and TA Luft.
using AMESA could close the gap between reality and target results. AMESA provides more informations on dioxin emissions than the usual
The AMESA can be used, for example, in refuse incinerators, hazardous material incinerators, medical waste burners, cement kilns etc.
Special Features
- Uses the well-known adsorption method
- Information on monthly, 2-weekly or weekly mean value of
dioxin/furan emissions by analysis of mixed sample (XAD-II cartridge) in laboratory
- Additional information on flue gas velocity, sample gas flow volume, flue gas and cartridge temperature as half-hourly average. Optional up to 4 informations like e.g. O2, CO2, CO, HCl, dust etc. can be recorded and saved half-hourly average.
- No collection of condensate and none of the associated
handling problems during monitoring over long periods
- Broadly based measuring range for dioxin/furan concentrations between 0.0001 and 10 ng/m³ (as TE to NATO CCMS model).
- Sampling period between 6 hours and 4 weeks possible
|  | Advantages Reduced running costs by minimizing
the useof additives
- Reduced costs by optimizing the built-in dioxin reduction stages
- Input control in wooden incinerators is no
more needed
- Minimizing running and maintenance costs
by monitoring the reduction in furnace temperature
- Minimizing handling costs, due to no
sampling of the condensate
Achieving a “transparent flue” and the
environmental acceptance that goes with it
|  | emission control technology emission control technology | |
|
|
<